20 Eos Family Show Control
Relay Outputs
Eos Family consoles can trigger relay outputs on Net3 I/O Gateways and on the local relay out on
Gio, Ion, and Element consoles. Relay outputs are also often called remote triggers, contact
closures, or contact outputs. Relay outputs are controlled by external links in cues. To program a
relay, there are two pieces of information that are very important, the ACN Group ID and the relay
address. Remember, the ACN Group ID is programmed into the gateway using GCE. You can
enter relay information using the following syntax:
[Cue] [1] {Execute} {Relay} [1] [/] [2] {On} [Enter] - 1 is the Group ID and the 2 is the relay
output address.