22 Eos Family Show Control
Stop
When accompanying a MIDI “Stop” command, data for the following fields will result in the following
effects:
Resume
When accompanying a MIDI “Resume” command, data for the following fields will result in the
following effects:
Set
The “Set” command allows MSC to control potentiometers using both a numeric control number
(which specifies the potentiometer) and a data field (which controls the level: 0-100). Control values
are as follows
Accompanying any of these indications in the MSC data, a numeric value of 0-100 would set the
specified potentiometer to that level.
All other control values are ignored.
Fire
This command fires a macro. MSC supports macros 1 through 127 only. Therefore a numeric value
of 1 - 127 followed by 00 (in hex) would accompany this command.
Cue Data
Field
List Data
Field
Effect
Cue List Stops the specified cue & list (if running)
Cue - Stops the running cue from the default cue list
- List Stops the current cue from the specified list
- - Stops all cues
Cue Data
Field
List Data
Field
Effect
Cue List Resumes the specified cue & list (if stopped)
Cue - Resumes the specified cue in the default cue list
- List Resumes the current cue in the specified list
- - Resumes all stopped cues
Control
Value
Data Field Indication
1-127 0-100 Submaster 1-127
128 0-100 Primary playback in
129 0-100 Primary playback out
510 0-100 Grandmaster
Note:
Levels transmitted must be followed with 00 (in hex) in order to be interpreted.