Express 125/250 User Manual, v.3.1 199
• Out - The Out Time, the meaning of which depends upon whether the
effect has a positive or negative attribute. For a positive effect, the
Out Time is the time the effect step takes to fade from its High Level
to its Low Level. For a negative effect, the Out Time is the time the
effect step takes to fade from its Low Level to its High Level. Default
Out Time is zero seconds.
• Lo - Known as Low Level, this is the lowest level the effect is allowed
to reach. The default Low Level is zero.
• Hi - Known as High Level, this is the highest level the effect is allowed
to reach. The default High Level is Full.
Effects in Stage
You can also create effects in the normal Stage display, where you can
see effect steps as you create them. The only difference between effects
and other types of cues in this display lies in the information provided in
the Attribute Bar.
Below is an illustration of the Stage display for an effect cue. The
illustration shows the softkeys presented and information contained in the
Attribute Bar when step 7 of this cue is identified.
85.
For the default condition of 0/0/0 for In/Dwell/Out, however, the step has an
instantaneous In fade, remains there for the entire Step Time and then has an
instantaneous Out fade.